    1 Scope

    1.1 The requirements in Part i of this Standard apply to enclosed capacitors with integral protection intended to reduce the risk of rupture and venting of the capacitor enclosure under internal fault conditions. These requirements apply to capacitors with expansion type protection rated 5 kilovolts or less, and capacitors with segmented film type protection rated 2 kilovolts or less that are intended for use with appliances, lighting equipment, air conditioning and refrigeration equipment, motors, and the like, that comply with the requirements for such appliances and equipment.


    1.1 revised July 26, 2012

    1.1.1 The requirements of Part i may also be used to evaluate the construction only of these types of capacitors with ratings greater than the values noted in 1.1 but no greater than 7.2 kilovolts. Capacitors employing polymeric enclosures or capacitors employing a partial metallic enclosure (i.e. remainder of enclosure such as the cap/cover which is not crimped to the case) that are not provided with internal protection and intended to be located in circuits not requiring fault current protection may be evaluated using only the construction requirements of Part i.


    1.1.1 revised July 26, 2012

    1.2 The requirements in Part ii of this standard apply to general-use power-factor-correction units consisting of one or more capacitors with or without protective fusing or overloads, with or without a switch or other disconnect device all within a protective enclosure; rated 600 volts maximum and intended for power-factor correction of circuits in accordance with the National Electrical Code, ANSI/NFPA 70. This equipment is intended for installation in ordinary locations, in accordance with the National Electrical Code, ANSI/NFPA 70, where the ambient temperature does not exceed 40°C (104°F) maximum.

    The requirements of Part ii of this standard do not apply to power factor correction units containing automatic or other circuit monitoring/conditioning controls or automatic systems of multiple connected power factor correction units. Power factor correction units with these additional features shall be evaluated to the Standard for Industrial Control Panels, UL 508A as an industrial control panel.


    1.2 revised effective May 21, 2012

    1.2.1 A component capacitor used in a power factor correction unit as described in Part ii of this Standard has been evaluated for across-the-line applications in accordance with Part i of this Standard and has been evaluated for a minimum fault current rating of 10K AFC.


    1.2.1 revised March 3, 2008

    1.2.2 The requirements of Supplement sa apply to electrolytic capacitors for motor start or similar applications including dc circuits rated 600 V or less.


    1.2.2 added March 3, 2008

    1.3 A capacitor that complies with the requirements in Part i of this standard is intended to be mounted within an appliance or within equipment for which an acceptable outer enclosure is provided.

    1.4 The requirements in Part i and Part ii do not apply to capacitors covered by the Standard for Across-the-Line, Antenna Coupling, and Line-by-Pass Capacitors for Radio- and Television-Type Appliances, UL 1414 .

    1.5 Other types of capacitors may be investigated to establish compliance with these requirements, and with such additional test criteria as may be found necessary.

    1.6 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.


    1.6 revised March 3, 2008

  • TABLE OF CONTENTS
    Expand All

    • Cover
    • Transmittal
    • Table of Contents
    • UL Foreword
      • Body
        • Part
          • INTRODUCTION
          • 1 Scope
          • 2 Glossary
          • 3 General
            • 3.1 Components
            • 3.2 Units of measurement
            • 3.3 Undated references
        • PART I – CAPACITORS
          • CONSTRUCTION
          • 4 Enclosure
            • 4.1 General
            • 4.2 Metallic
            • 4.3 Nonmetallic
          • 5 Internal Protection Bridge
          • 6 Insulating Material
          • 7 Leads, Terminals and Internal Wiring
          • 8 Spacings
          • PERFORMANCE
          • 9 Pull-Out Test
          • 9A Conductor Insulation Test
          • 9B Mold Stress Relief Test (Terminals Blocks/Terminal Connectors)
          • 10 Fault-Current Test
            • 10.1 General
            • 10.2 Sample preparation
            • 10.3 Test method
            • 10.3A Test method
            • 10.4 Restrike test (expansion type protection only)
          • 11 Dielectric Voltage-Withstand Test
          • 11A Dielectric Voltage-Withstand Test
          • MANUFACTURING AND PRODUCTION TESTS
          • 12 Dielectric Voltage-Withstand Test
          • MARKINGS
          • 13 General
        • PART II – POWER-FACTOR CORRECTION UNITS
          • GENERAL
          • 14 Terminology
          • CONSTRUCTION
          • 15 Frame and Enclosure
          • 16 Accessibility of Uninsulated Live Parts, Moving Parts, and Film-Coated Wire
          • 17 Protection Against Risks of Electric Shock and Injury to Persons
            • 17.1 General
            • 17.2 Live parts
            • 17.3 Moving parts
            • 17.4 Mechanical servicing
            • 17.5 Electrical servicing
          • 18 Assembly
          • 19 Protection Against Corrosion
          • 20 Supply Connections
          • 21 Wiring Terminals and Leads
          • 21A Wire Bending Space
          • 22 Current-Carrying Parts
          • 23 Internal Wiring
            • 23.1 General
            • 23.2 Protection of wiring
            • 23.3 Electrical connections
          • 24 Separation of Circuits
            • 24.1 General
            • 24.2 Separation barriers
            • 24.3 Field wiring
          • 25 Insulating Materials
          • 26 Switches and Controls
          • 27 Overload-Protective Devices
          • 28 Fuses and Fuseholders
          • 29 Printed Wiring
          • 30 Spacings
            • 30.1 General
            • 30.2 Alternative spacings
            • 30.3 Insulating liners or barriers for the reduction of spacings
            • 30.4 Spacings for controlled environment applications
          • 31 Secondary Circuits
          • 31A Secondary Circuits
            • 31A.1 General
            • 31A.2 Limited power sources
          • 32 Grounding Connections
          • 33 Bonding of Internal Parts
          • PERFORMANCE
          • 34 General
          • 35 Power Input Test
          • 36 Draining of Charge Test
          • 37 Open-Circuit Potential Test
          • 37A Secondary Circuit Evaluations
            • 37A.1 SELV determination
            • 37A.2 Limited power determination
          • 38 Temperature Test
          • 39 Dielectric Voltage-Withstand Test
          • 40 Compression Test
          • 41 Deflection Test
          • 42 Tightening Torque Test
          • 43 Static Load Test
          • MANUFACTURING AND PRODUCTION TESTS
          • 44 Dielectric Voltage-Withstand Test
          • RATINGS
          • 45 Details
          • MARKINGS
          • 46 General
          • 47 Installation Instructions
          • OUTDOOR-USE UNITS
          • 48 General
          • 49 Construction
            • 49.1 General
            • 49.2 Corrosion protection
          • 50 Rain Test
          • 51 Gasket Tests
          • 52 Metallic Coating Thickness Test
          • 53 Markings
    • Electrolytic Capacitors
    • APPENDIX A