UL 636
Standard for Holdup Alarm Units and Systems

DETAILS
Edition Number:11SCC Approved:--
Edition Date:2018-01-30DOD Approved: 1987-07-30
Price Code:BANSI Approved: 2018-01-30
Type:ulstd

  • SCOPE

    1 Scope

    1.1 These requirements cover holdup alarm systems of the remote-station type intended for installation in banks, stores, cashiers' cages, pay offices, and the like to provide a means of transmitting a silent call for help in the event of interior robbery. These systems are divided into the three classes listed in 1.2 and are defined under Extent of Protection, Section 90.

    1.2 The three classes are: Bandit-Resisting Enclosure and Alarm, Semiautomatic Alarm, and Manual Alarm.

  • TABLE OF CONTENTS
    Expand All

    • Cover
    • Transmittal
    • Table of Contents
      • Body
        • INTRODUCTION
          • 1 Scope
          • 2 Components
          • 3 Units of Measurement
          • 4 Undated References
          • 5 Terminology
          • 6 Glossary
        • INSTRUCTIONS AND DRAWINGS
          • 7 General
        • CONSTRUCTION
          • ASSEMBLY
          • 8 General
          • 9 Protection of Service Personnel
          • 10 Enclosures
            • 10.1 General
            • 10.2 Openings
            • 10.3 Cast Metal
            • 10.4 Sheet Metal
            • 10.5 Nonmetallic
            • 10.6 Doors, covers, and guards
            • 10.7 Screens and expanded metal
          • 11 Electric Shock
          • 12 Corrosion Protection
        • FIELD WIRING CONNECTIONS
          • 13 General
            • 13.1 General
            • 13.2 Field wiring compartment
            • 13.3 Terminals – general application
            • 13.4 Terminals – qualified application
            • 13.5 Leads
            • 13.6 Cords and plugs
            • 13.7 Polarity identification
          • 14 Grounding
        • INTERNAL WIRING
          • 15 General
          • 16 Separation of Circuits
          • 17 Bonding for Grounding
        • COMPONENTS – ELECTRICAL
          • 18 General
            • 18.1 Mounting of components
            • 18.2 Insulating materials
            • 18.3 Current-carrying parts
            • 18.4 Bushings
          • 19 Capacitors
          • 20 Overcurrent Protection
          • 21 Semiconductors
          • 22 Switches
          • 23 Transformers, Coils, and Relays
        • SPACINGS
          • 24 General
        • PERFORMANCE
          • 25 General
          • 26 Test Samples and Miscellaneous Data
          • 27 FCC Requirements
          • 28 Test Voltages
        • TESTS
          • 29 Normal Operation Test
          • 30 Circuit Protection Test
          • 31 Input Test
          • 32 Power Supply Test
            • 32.1 General
            • 32.2 Battery tests
          • 33 Power Failure Test
          • 34 Component Malfunction Test
          • 35 Undervoltage Operation Test
          • 36 Overvoltage Operation Test
          • 37 Variable Ambient Temperature Test
          • 38 Humidity Test
          • 39 Leakage Current Tests for Cord-Connected Products
          • 40 Electric Shock Current Test
          • 41 Overload Test
            • 41.1 General
            • 41.2 Separately energized circuits
          • 42 Endurance Test
            • 42.1 General
            • 42.2 Separately energized circuits
          • 43 Jarring Test
          • 44 Temperature Test
          • 45 Dielectric Voltage-Withstand Test
          • 46 Abnormal Operation Test
          • 47 Electrical Transient Tests
            • 47.1 General
            • 47.2 Supply line transients
            • 47.3 Internally induced transients
            • 47.4 Input/output circuit transients
          • 48 AC Induction Test
          • 49 Radio Frequency Interference Test
          • 50 Polymeric Materials Test
          • 51 Battery Replacement Test
          • 52 Drop Test
          • 53 Strain Relief Test
            • 53.1 Flexible cords
            • 53.2 Field-wiring leads
          • 54 Ignition Through Bottom-Panel Openings Tests
            • 54.1 General
            • 54.2 Hot, flaming oil
            • 54.3 Molten PVC and copper
          • 55 Mechanical Strength Tests for Enclosures
          • 56 Tests on Special Terminal Assemblies
            • 56.1 General
            • 56.2 Disconnection and reconnection
            • 56.3 Mechanical secureness
            • 56.4 Flexing test
            • 56.5 Millivolt drop test
            • 56.6 Temperature test
          • 57 Marking Permanency Tests
        • SHORT RANGE RADIO FREQUENCY (RF) OPERATED INITIATING DEVICES
          • 58 General
          • 59 Time to Report Alarm
          • 60 Inoperative Transmitter Reporting
          • 61 Battery Status Indication
          • 62 Tamper Protection
          • 63 Interference Protection
          • 64 Reference Level Determination
            • 64.1 Method I
            • 64.2 Method 2
          • 65 Interference Immunity
          • 66 Frequency Selectivity
          • 67 Clash
          • 68 Clash Error
          • 69 Error (Falsing) Rate
          • 70 Throughput Rate
          • 71 Transmitter Stability Test
          • 72 Transmitter Accelerated Aging Test
          • 73 Installation Instructions and User Manual
          • 74 Test
          • 75 Drop Test
        • MANUFACTURING AND PRODUCTION TESTS
          • 76 General
          • 77 Production Line Dielectric Voltage-Withstand Test for High-Voltage Products
          • 78 Production Line Grounding Continuity Test for High-Voltage Cord-Connected Products
        • MARKING
          • 79 General
        • ACCESSORY EQUIPMENT
          • 80 General
          • 81 Construction
          • 82 Performance (Installation) Test
          • 83 Markings
        • OPERATION AND ELECTRICAL SUPERVISION
          • 84 General
        • POWER SUPPLIES
          • 85 General
          • 86 Battery Standby
          • 87 Rechargeable Batteries
          • 88 Nonrechargeable Batteries
        • INSTALLATION
          • 89 Types of Remote Stations
          • 90 Extent of Protection
            • 90.1 General
            • 90.2 Bandit-Resisting Enclosure and Alarm
            • 90.3 Semiautomatic Alarm
            • 90.4 Manual Alarm
        • OUTSIDE CABLES
          • 91 General
            • 91.1 General
            • 91.2 Underground wires
            • 91.3 Overhead wires
        • WIRES INSIDE BUILDING
          • 92 General
            • 92.1 General
            • 92.2 Running and fastening
            • 92.3 Splices and connections
            • 92.4 Separation of interconnecting and protective wiring from other wiring or objects
            • 92.5 Passage through floors and walls
        • MAINTENANCE
          • 93 General
    • Appendix A