  • SCOPE

    1 Scope and normative references

    This clause of Part 1 is applicable except as follows:

    1.1 Replacement:

    This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps.

    This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J.

    Requirements concerning the testing of the combination of ballast and thermal protector are given in IEC 61347-1.

    1.1DV Modification to the third paragraph of the part 2:

    Add "and UL 935." to the end of the sentence.

    1.1.1 This standard applies to the inherent safety, to the operating values, operating times, and operating sequences where such are associated with equipment safety and to the testing of thermal protectors used to protect ballasts for tubular lamps from overheating.

    This standard applies to thermal protectors for ballasts within the scope of IEC 61347-2-8.

    Thermal protectors covered by this standard may be suitable for ballasts for other discharge lamps such as ballasts under the scope of IEC 61347-2-9.

    Throughout this standard the word "protector" means "self-resetting thermal ballast protector."

    1.1.1DV Modification to the second paragraph of the part 2:

    Add "and UL 935." to the end of the sentence.

    1.1.2 This standard is not applicable to other means used to protect ballasts.

    1.1.3 This standard does not apply to a manual device for opening the circuit.

    1.2 Replacement:

    This standard applies to protectors for use with ballasts for use on a.c. supplies up to 690 V at 50 Hz or 60 Hz.

    1.3 Replacement:

    This standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies.

    1.101DV Addition of the following to the part 2:

    In IEC terminology, "safety" is defined as an acceptable level of risk. This is consistent with the intentions of UL requirements to reduce the risk of fire, shock, or injury to persons.

    1.5 Normative references

    Addition:

    1.5

    IEC 61347-1,  Lamp controlgear – Part 1: General and safety requirements

    IEC 61347-2-8,  Lamp controlgear – Part 2-8: Particular requirements for ballasts for fluorescent lamps

    IEC 61347-2-9,  Lamp controlgear – Part 2-9: Particular requirements for discharge lamps (excluding fluorescent lamps)

    1.5DV Add the following UL reference:

    1.5DV

    UL 935 Fluorescent-Lamp Ballasts

  • TABLE OF CONTENTS
    Expand All

    • Cover
    • Transmittal
    • Table of Contents
    • UL Preface
    • Deviations
    • IEC Foreword
    • IEC Preface
      • AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE – Part 2: Particular requirements for Thermal Protectors for Ballasts for Tubular Fluorescent Lamps
        • Section
          • 1 Scope and normative references
            • 1.5 Normative references
          • 2 Definitions
          • 3 General requirements
          • 4 General notes on tests
            • 4.2 Samples required
          • 5 Rating
          • 6 Classification
            • 6.3 According to their purpose
            • 6.4 According to features of automatic action
          • 7 Information
          • 8 Protection against electric shock
          • 9 Provision for protective earthing
          • 10 Terminals and terminations
          • 11 Constructional requirements
            • 11.3.4 Setting by the manufacturer
          • 12 Moisture and dust resistance
            • 12.2 Protection against humid conditions
          • 13 Electric strength and insulation resistance
          • 14 Heating
          • 15 Manufacturing deviation and drift
          • 16 Environmental stress
          • 17 EnduranceThis clause of Part 1 is replaced as follows:17 Overload, endurance and limited short-circuit
            • 17.1 General requirements
            • 17.2 Test voltage
            • 17.3 Electrical strength requirements
            • 17.4 Limited short-circuit
          • 18 Mechanical strength
          • 19 Threaded parts and connections
          • 20 Creepage distances, clearances and distances through solid insulation
          • 21 Resistance to heat, fire and tracking
          • 22 Resistance to corrosion
          • 23 Electromagnetic compatibility (EMC) requirements – Emission
          • 24 Components
          • 25 Normal operation
          • 26 Electromagnetic compatibility (EMC) requirements – Immunity
          • 27 Abnormal operation
          • 28 Guidance on the use of electronic disconnection
        • Figures
    • Annexes
    • Annex C(normative) Cotton used for mercury switch test(not applicable in the countries members of CENELEC)
    • Annex E(normative) Circuit for measuring leakage current
    • ANNEX 3.DVA – Manufacturing and Production Tests (normative)