    1 Scope

    1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code Part I, CSA C22.1, in non-hazardous locations, and the Instalaciones Eléctricas (utilización), NOM-001-SEDE.

    1.2 These devices incorporate resistance, reactance, or electronic (solid-state) type ballasts or power supplies. These devices employ various lamp technologies including, but not limited to, incandescent, fluorescent, high-intensity discharge lamps, light-emitting diodes.

    1.3 These requirements also include Supplemental Requirements for Light-Emitting Diodes (LED), Supplement sa, for:

    a)    Self-contained LED lamps, rated 120 to 347 V AC nominal for connection to screw-, pin-base, and recessed single contact (RSC or R7) lampholders,

    b)    Lamps for replacement of an ANSI standardized fluorescent lamp, and consisting of light-emitting-diode (LED) lamp technologies, with control circuitry, and a driver or power supply. The LED driver and control circuitry will be either integral with the lamp or remote from the lamp, and

    c)    Component LED lamps, with or without control circuitry, an ANSI base other than bases mentioned in (a), for connection to LED driver having a low voltage output, such as replacement for tungsten-halogen, MR11 and MR16 shaped lamps.

    1.4 This standard does not apply to medium-to-medium base (E26) fittings that incorporate controls such as photocells, motion detectors, radio controls, or dimmers covered by other standards.

    1.5 These devices are not intended for use with emergency exit fixtures or emergency exit lights.

  • TABLE OF CONTENTS
    Expand All

    • Cover
    • Transmittal
    • UL Harmonized Standard Title Page
    • Table of Contents
      • Body
        • 1 Scope
        • 2 Reference Publications
          • 2.1 Normative references
          • 2.2 Informative references
        • 3 Definitions
        • 4 General Requirements
          • 4.1 Components
          • 4.2 Application of requirements
          • 4.3 Units of measurement
          • 4.4 Assembly and packaging
          • 4.5 Principles
        • 5 Mechanical Construction
          • 5.1 Enclosures
          • 5.2 Openings
          • 5.3 Polymeric materials
          • 5.4 Weight and moment
        • 6 Electrical Construction
          • 6.1 Lamp bases and lampholders
          • 6.2 Current-carrying parts
          • 6.3 Printed circuit boards
          • 6.4 Ballasts and LED drivers
          • 6.5 Power capacitors
          • 6.6 Spacing of electrical parts
          • 6.7 Accessibility of live parts
          • 6.8 Light source – fluorescent lamps
          • 6.9 Light source – light emitting diodes (LED)
          • 6.10 Light source – non-discharge lamps
        • 7 Environmental Locations
          • 7.1 Dry locations
          • 7.2 Damp locations
          • 7.3 Wet locations
        • 8 Tests
          • 8.1 General
          • 8.2 Input measurements
          • 8.3 Lamp starting and operating measurements
          • 8.4 Leakage-current test
          • 8.5 Temperature test
          • 8.6 Dielectric voltage-withstand test
          • 8.7 Harmonic distortion test
          • 8.8 Drop impact test
          • 8.9 Mold-stress relief conditioning
          • 8.10 Deflection test
          • 8.11 Strain relief test for lamp connectors
          • 8.12 Tests of dimmer circuits
          • 8.13 Humidity conditioning
          • 8.14 Water spray test
          • 8.15 Cold impact test
          • 8.16 Lamp fault conditions test
          • 8.17 End-of-lamp-life tests for fluorescent lamp adapters
          • 8.18 End-of-life test for integral, self-ballasted fluorescent lamps – one filament emission-mix-free test
          • 8.19 15-VA available power measurement test
        • 9 Test Apparatus
          • 9.1 General
          • 9.2 Instrumentation
          • 9.3 Thermocouples
          • 9.4 Plywood test box material
          • 9.5 Temperature test box
          • 9.6 Articulated probe
          • 9.7 Water spray apparatus
          • 9.8 Cheesecloth
        • 10 Device Markings
          • 10.1 General
          • 10.2 Identifications and ratings
          • 10.3 Marking requirements in Mexico
          • 10.4 Instructions
    • ADDITIONAL REQUIREMENTS FOR LED LAMPS AND FLUORESCENT LAMP ADAPTERS INTENDED AS DIRECT REPLACEMENTS FOR FLUORESCENT LAMPS
    • ANNEX A(normative)Standards for Components
    • ANNEX B (CAN)(normative)Markings – French Translations
    • ANNEX C (MEX)(normative)Markings – Spanish Translations
    • ANNEX D(normative)Manufacturing and Production Tests
    • ANNEX E (CAN)(normative)Printed Circuit Boards
    • ANNEX F(informative)Pictograms
    • ANNEX G(informative)Metric Conversion Information