  • SCOPE

    1 Scope

    1.1 This Standard specifies the requirements for distribution (power) cables, and control and signal cables for installation aboard marine vessels, fixed and floating offshore petroleum facilities, and mobile offshore drilling units (MODUs), in accordance with industry installation standards and the regulations of the authorities having jurisdiction. The cables are single or multi-conductor, with or without metal armor and/or jacket, and are rated 300 V – 35 kV.

    1.2 These cables are not intended for use in accordance with the National Electrical Code (NEC), ANSI/NFPA 70. Cables that also meet the requirements for use with the NEC may be additionally marked with the appropriate "Type" designation from the NEC.

  • TABLE OF CONTENTS
    Expand All

    • Cover
    • Transmittal
    • Table of Contents
      • Body
        • INTRODUCTION
          • 1 Scope
          • 2 Units of Measurement
          • 3 References
        • CONSTRUCTION
          • 4 Copper Conductors
            • 4.1 General
            • 4.2 Composition
            • 4.3 Stranding
            • 4.4 Joints
            • 4.5 Conductor stress control layer (for cables rated above 2 kV)
          • 5 Insulation
            • 5.1 General
            • 5.2 Separator
            • 5.3 Thickness of extruded insulation
            • 5.4 Properties of insulation
          • 6 Insulation Shield
          • 7 Binder or Separator
          • 8 Braids
          • 9 Conductor Identification
          • 10 Shielding
          • 11 Individually Shielded Components and Overall Shielding
          • 12 Cabling
          • 13 Fillers
          • 14 Cable Jackets
            • 14.1 General
            • 14.2 Integral insulation/jacket
            • 14.3 Jacket thickness
          • 15 Metal Wire Armor (Optional)
            • 15.1 General
            • 15.2 Aluminum armor
            • 15.3 Commercial bronze armor
            • 15.4 Copper armor
          • 16 Corrugated Aluminum Sheath (Optional)
          • 17 Paint
          • 18 Jacket Over Armor
          • 19 Equipment Grounding Conductors
          • 20 System Ground
        • PERFORMANCE
          • 21 General
          • 22 Low Temperature Bend Test
          • 23 Low Temperature Impact Test
          • 24 Sunlight/Weather Resistance Test
          • 25 Flame Test
          • 26 Ease of Stripping Test
          • 27 Salt Water Immersion Test
          • 28 Oil Compatibility Test
          • 29 Pulling Through Metal Plates Test
          • 30 Bending Endurance Test
          • 31 Long-Term Insulation Resistance
          • 32 Heat Deformation Test
          • 33 Heat Shock Test of Jacket
          • 34 Tension Set of Jacket
          • 35 Hot Oil Resistance
          • 36 Vertical-Tray Fire and Smoke-Release Test for Cables with “ST1” Marking
        • MANUFACTURING AND PRODUCTION LINE TESTS
          • 37 Spark Test (0 – 2 kV Unshielded Cables)
          • 38 Dielectric Withstand Test on Finished Cable (0 – 2.4 kV Cables)
          • 39 Insulation Resistance Test on Finished Cable (0 – 2.4 kV Cables)
        • MARKINGS
          • 40 Cable Identification
          • 41 Cable Type Designation
            • 41.1 General
            • 41.2 Specific cable types
          • 42 Package Markings
    • APPENDIX A – RECOMMENDED PRACTICE FOR COLOR CODE FOR CONTROL AND SIGNAL CABLES