    1 Scope

    1.1 These requirements cover power distribution blocks that are rated 1000 volts or less and intended to be used on either the line side or load side of service equipment in accordance with the National Electrical Code, NFPA 70. These blocks are used for splicing and tapping conductors in order to distribute power to separate circuits or loads.

    1.2 A power-distribution block consists of one or more connectors mounted on an insulating base. Each connector has provision for one or more incoming conductors and multiple tap-off conductors. A tap-off conductor is of the same or smaller size as the incoming conductor. The connectors may be of the lay-in construction which do not require the incoming conductor to be terminated.

    1.3 A power distribution block is intended to permanently support and insulate the wire terminations and joints of each polarity from each other, and from the surface on which the power distribution block is mounted. A power distribution block may also be provided with an insulating cover.

    1.4 These requirements do not cover terminal blocks which are covered by the Standard for Terminal Blocks, UL 1059.

  • TABLE OF CONTENTS
    Expand All

    • Outline Title Page
    • Table of Contents
      • Body
        • INTRODUCTION
          • 1 Scope
          • 2 Glossary
          • 3 Units of Measurement
          • 4 Updated References
          • 5 Components
        • CONSTRUCTION
          • 6 Materials
            • 6.1 Current-carrying parts
            • 6.2 Insulation
          • 7 Terminal Assemblies
            • 7.1 General
            • 7.2 Tightening torque
            • 7.3 Minimum size of conductor for line side service applications
          • 8 Spacings
            • 8.1 General
            • 8.2 Insulating barriers
            • 8.3 Insulating Covers
        • PERFORMANCE
          • 9 General
          • 10 Temperature Test
          • 11 Dielectric Voltage-Withstand Tests
            • 11.1 General
            • 11.2 Clamped insulating joint
            • 11.3 Insulating barriers
          • 12 Strength of Insulating Base and Support Test
          • 13 Short-Circuit Current Test
        • RATINGS
          • 14 General
          • 15 Short-Circuit Current
        • MARKINGS
          • 16 General
          • 17 Connectors
          • 18 Short Circuit Current
          • 19 Insulating Covers
            • 19.1 General
            • 19.2 Use on line side of service equipment
          • 20 Permanence of Marking